Sign In | Join Free | My wpc-board.com
China HENAN UME CABLE CO., LTD. logo
HENAN UME CABLE CO., LTD.
Proffesional partner solution for wire and cable
Verified Supplier

1 Years

Home > Bare Conductor >

AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance

HENAN UME CABLE CO., LTD.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance

Model NO. : AAAC Conductor

Material Shape : Round Wire

Range of Application : Overhead

Certification : ISO9001, CE, SGS TUV

Brand : Ume

Third Party Inspection : Accepted

Sample : Free

Color : Customer Specified

OEM : Accepted

Transport Package : Drum

Specification : up to 1439MCM

Trademark : UME

Origin : China

HS Code : 7614900000

Supply Ability : 500, 000km Per Month

Type : Bare

Conductor Type : Stranded

Application : Overhead

Conductor Material : Aluminum Alloy

Sheath Material : None

Insulation Material : Bare

Samples : US$ 1/Piece 1 Piece(Min.Order) | Request Samp

Contact Now

Product Description

ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.


AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance
AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance





1. Applications
AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.

2. Construction
AAAC is concentric-lay- stranded, similar in construction and appearance with1350 grade aluminum conductors.They were developed to the need of economical conductor for overhead applications requiring higher strength than that of 1350 grade aluminum conductors, but without a steel core.

3. Standards
BS EN 50182, IEC 61089, DIN 48201, ASTM B399

Product Parameters

BS EN 50182

Code
Name
Nominal
Area
No. / Dia. of Wire Approx. Overall
Dia.
Approx.
Weight
Calculated Breaking
Load
Max. DC Resistance
at 20° C
mm2 No./mm mm kg/km kN Ω/km
Box 18.8 7/1.85 5.55 51.4 5.6 1.7480
Acacia 23.8 7/2.08 6.24 64.9 7.0 1.3828
Almond 30.1 7/2.34 7.02 82.2 8.9 1.0926
Cedar 35.5 7/2.54 7.62 96.8 10.5 0.9273
Deodar 42.2 7/2.77 8.31 115.2 12.4 0.7797
Fir 47.8 7/2.95 8.85 130.6 14.1 0.6875
Hazel 59.9 7/3.30 9.90 163.4 17.7 0.5494
Pine 71.6 7/3.61 10.83 195.6 21.1 0.4591
Holly 84.1 7/3.91 11.73 229.5 24.8 0.3913
Willow 89.7 7/4.04 12.12 245.0 26.5 0.3665
Oak 118.9 7/4.65 13.95 324.5 35.1 0.2767
Mulberry 150.9 19/3.18 15.90 414.3 44.5 0.2192
Ash 180.7 19/3.48 17.40 496.1 53.3 0.1830
Elm 211.0 19/3.76 18.80 579.2 62.2 0.1568
Poplar 239.4 37/2.87 20.09 659.4 70.6 0.1387
Sycamore 303.2 37/3.23 22.61 835.2 89.4 0.1095
Upas 362.1 37/3.53 24.71 997.5 106.8 0.0917
Yew 479.0 37/4.06 28.42 1319.6 141.3 0.0693
Totara 498.1 37/4.14 28.98 1372.1 146.9 0.0666
Rubus 586.9 61/3.50 31.50 1622.0 173.1 0.0567
Sorbus 659.4 61/3.71 33.39 1822.5 194.5 0.0505
Araucaria 821.1 61/4.14 37.26 2269.4 242.2 0.0406
Redwood 996.2 61/4.56 41.04 2753.2 293.9 0.0334

IEC 61089

Code
Name
Nominal
Area
No. / Dia. of Wire Approx. Overall
Dia.
Approx.
Weight
Calculated Breaking
Load
Max. DC Resistance
at 20° C
mm2 No./mm mm kg/km kN Ω/km
16 18.4 7/1.83 5.49 50.4 5.4 1.7896
25 28.8 7/2.29 6.87 78.7 8.5 1.1453
40 46 7/2.89 8.67 125.9 13.6 0.7158
63 72.5 7/3.63 10.89 198.3 21.4 0.4545
100 115 19/2.78 13.90 316.3 34.0 0.2877
125 144 19/3.10 15.50 395.4 42.4 0.2302
160 184 19/3.51 17.55 506.1 54.3 0.1798
200 230 19/3.93 19.65 632.7 67.9 0.1439
250 288 19/4.39 21.95 790.8 84.9 0.1151
315 363 37/3.53 24.71 998.9 107.0 0.0916
400 460 37/3.98 27.86 1268.4 135.8 0.0721
450 518 37/4.22 29.54 1426.9 152.8 0.0641
500 575 37/4.45 31.15 1585.5 169.8 0.0577
560 645 61/3.67 33.03 1778.4 190.1 0.0516
630 725 61/3.89 35.01 2000.7 213.9 0.0458
710 817 61/4.13 37.17 2254.8 241.1 0.0407
800 921 61/4.38 39.42 2540.6 271.6 0.0361
900 1036 91/3.81 41.91 2861.1 305.6 0.0321
1000 1151 91/4.01 44.11 3179.0 339.5 0.0289
1120 1289 91/4.25 46.75 3560.5 380.3 0.0258
1250 1439 91/4.49 49.39 3973.7 424.4 0.0231

DIN 48201

Nominal
Area
Actual
Area
No. / Dia. of Wire Approx. Overall
Dia.
Approx.
Weight
Calculated Breaking
Load
Max. DC Resistance
at 20° C
mm2 mm2 No./mm mm kg/km kN Ω/km
16 15.9 7/1.70 5.1 43 4.4 2.0742
25 24.3 7/2.10 6.3 66 6.8 1.3593
35 34.4 7/2.50 7.5 94 9.6 0.9591
50 49.5 7/3.00 9.0 135 13.8 0.6660
50 48.4 19/1.80 9.0 133 13.5 0.6849
70 65.8 19/2.10 10.5 181 18.4 0.5032
95 93.3 19/2.50 12.5 256 26.1 0.3551
120 117.0 19/2.80 14.0 322 32.7 0.2831
150 147.1 37/2.25 15.8 406 41.1 0.2256
185 181.6 37/2.50 17.5 500 50.7 0.1828
240 242.5 61/2.25 20.3 670 67.7 0.1371
300 299.4 61/2.50 22.5 827 83.6 0.1110
400 400.1 61/2.89 26.0 1104 111.8 0.0831
500 499.8 61/3.23 29.1 1379 139.6 0.0665
625 626.2 91/2.96 32.6 1732 174.9 0.0531
800 802.1 91/3.35 36.9 2218 224.0 0.0415
1000 999.7 91/3.74 41.1 2767 279.2 0.0333

ASTM B399

Code
Name
Total Area 1350 Grade Equivalent No. / Dia. of Wire Approx. Overall
Dia.
Approx.
Weight
Calculated Breaking
Load
Max. DC Resistance
at 20° C
AWG or MCM mm2 AWG or MCM No./mm mm kg/km kN Ω/km
Akron 30.6 15.5 6 7/1.68 5.04 43 4.9 2.1588
Alton 48.7 24.7 4 7/2.12 6.36 68 7.8 1.3557
Ames 77.5 39.2 2 7/2.67 8.01 108 12.4 0.8547
Azusa 123.3 62.4 1 7/3.37 10.11 171 18.9 0.5365
Anaheim 155.4 78.6 2/0 7/3.78 11.34 216 23.8 0.4264
Amherst 195.7 99.3 3/0 7/4.25 12.75 272 30.0 0.3373
Alliance 246.9 125.1 4/0 7/4.77 14.31 343 37.8 0.2678
Butte 312.8 158.6 266.8 19/3.26 16.30 435 46.5 0.2112
Canton 394.5 199.9 336.4 19/3.66 18.30 548 58.6 0.1676
Cairo 465.4 236.4 397.5 19/3.98 19.90 649 69.3 0.1417
Darien 559.5 283.6 477 19/4.36 21.80 778 83.1 0.1181
Elgin 652.6 331.0 556.5 19/4.71 23.55 908 97.0 0.1012
Flint 740.8 374.5 636 19/3.59 25.13 1028 107.4 0.0894
Greeley 927.2 469.6 795 19/4.02 28.14 1289 134.6 0.0713
Testing

HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!

Production:

  • Raw material inspection and test
  • Production process test
  • Unqualified product control
  • Regular test and examination
  • Finished product inspection
AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance

Certifications
UME CABLE has completed several third-party product certifications to ensure our customers that all of the wire and cable purchased and installed in your projects, will fully and consistently meet all criteria of the required production and performance standards, also you are guaranteed we (as the manufacturer) and the products supplied are both valid and continuously monitored by those globally recognized quality verification system listed as below: ISO9001, ISO14001, ISO45001, CE, SGS, TUV.
AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance


Packaging & Shipping

AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance
AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance


Customer Visit

AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance

Company Profile
AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance
UME CABLE is one of the leading companies in the production and distribution of cables and wires in China. As a manufacturer, we have supplied quality products to more than 50 countries. Our mission is to offer our customers the best quality cable and wire products at the most competitive price, to extend and zoom the business success of our partners, to make power reach where it is needed, to optimize the running utility grids, and ultimately, to power the world. Our version is to be the most customer-centric cable and wire company with our solid technology, enthusiastic services, and robust products.

UME Cable was founded in 1994, located in Zhengzhou Gongyi Huiguo Town, and occupies a total area of more than 200,000 square meters, with a building area of 20,000 square meters. The real capital assets are more than USD 6 million, with a total of 230 staff members, 35 of which are professional and technical experts. The land of our factory and employees numbers might not be the top scale of industry, but our highly automatic facilities and elite employees are the best in the industry will guarantee you a high yield rate achieved by strict cost and quality control, this is why we could quote better quality with the most competitive price within the market.

FAQ

Q1: Are you a manufacturer?
Yes, we are the manufacturer.

Q2: What are your main products?
Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor.

Q3: Do you provide samples? Is it free or extra?
Yes, we could offer the samples for free

Q4: Is the quality of your products guaranteed?
We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.

Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.

Q6: What is your payment term?
T/T or L/C

Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.






































































Wholesale AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance from china suppliers

AAAC Bare Conductor Transmission Line All Aluminum Alloy Conductor for Performance Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: HENAN UME CABLE CO., LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)